Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 304
Filtrar
1.
J Prosthet Dent ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38641480

RESUMO

STATEMENT OF PROBLEM: Multiple factors can influence the accuracy of intraoral scanners (IOSs). However, the impact of scan extension and starting quadrant on the accuracy of IOSs for fabricating tooth-supported crowns remains uncertain. PURPOSE: The purpose of the present in vitro study was to measure the influence of scan extension (half or complete arch scan) and the starting quadrant (same quadrant or contralateral quadrant of the location of the crown preparation) on the accuracy of four IOSs. MATERIAL AND METHODS: A typodont with a crown preparation on the left first molar was digitized (T710) to obtain a reference scan. Four scanner groups were created: TRIOS 5, PrimeScan, i700, and iTero. Then, 3 subgroups were defined based on the scan extension and starting quadrant: half arch (HA subgroup), complete arch scan starting on the left quadrant (CA-same subgroup), and complete arch scan starting on the right quadrant (CA-contralateral subgroup), (n=15). The reference scan was used as a control to measure the root mean square (RMS) error discrepancies with each experimental scan on the tooth preparation, margin of the tooth preparation, and adjacent tooth areas. Two-way ANOVA and pairwise multiple comparisons were used to analyze trueness (α=.05). The Levene and pairwise comparisons using the Wilcoxon Rank sum tests were used to analyze precision (α=.05). RESULTS: For the tooth preparation analysis, significant trueness and precision differences were found among the groups (P<.001) and subgroups (P<.001), with a significant interaction group×subgroup (P=.002). The iTero and TRIOS5 groups obtained better trueness than the PrimeScan and i700 groups (P<.001). Moreover, half arch scans obtained the best trueness, while the CA-contralateral scans obtained the worst trueness (P<.001). The iTero group showed the worst precision among the IOSs tested. For the margin of the tooth preparation evaluation, significant trueness and precision differences were found among the groups (P<.001) and subgroups (P<.001), with a significant interaction group×subgroup (P=.005). The iTero group obtained best trueness (P<.001), but the worst precision (P<.001) among the IOSs tested. Half arch scans obtained the best trueness and precision values. For the adjacent tooth analysis, trueness and precision differences were found among the groups (P<.001) and subgroups tested (P<.001), with a significant interaction group×subgroup (P=.005). The TRIOS 5 obtained the best trueness and precision. Half arch scans obtained the best accuracy. CONCLUSIONS: Scan extension and the starting quadrant impacted the scanning trueness and precision of the IOSs tested. Additionally, the IOSs showed varying scanning discrepancies depending on the scanning area assessed. Half arch scans presented the highest trueness and precision, and the complete arch scans in which the scan started in the contralateral quadrant of where the crown preparation was obtained the worst trueness and precision.

2.
Int J Prosthodont ; 37(7): 119-126, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38498863

RESUMO

PURPOSE: To evaluate the effect of model resin type and time interval on the dimensional stability of additively manufactured diagnostic casts. MATERIALS AND METHODS: Ten irreversible hydrocolloid impressions and 10 impressions from an intraoral scanner were made from a reference maxillary stone cast, which was also digitized with a laboratory scanner. Conventional impressions were poured in type III stone (SC), while digital impressions were used to additively manufacture casts with a nanographene-reinforced model resin (GP) or a model resin (DM). All casts were digitized with the same laboratory scanner 1 day (T0), 1 week (T1), 2 weeks (T2), 3 weeks (T3), and 4 weeks (T4) after fabrication. Cast scans were superimposed over the reference cast scan to evaluate dimensional stability. Data were analyzed with Bonferroni-corrected repeated measures ANOVA (α = .05). RESULTS: The interaction between the main factors (material type and time interval) affected anterior teeth deviations, while the individual main factors affected anterior teeth and entire-cast deviations (P ≤ .008). Within anterior teeth, DM had the lowest deviations at T3, and GP mostly had lower values at T2 and lower deviations at T3 than at T0 (P ≤ .041). SC had the highest pooled anterior teeth deviations, and GP had the highest pooled entire cast deviations (P < .001). T3 had lower pooled anterior teeth deviations than at T0, T1, and T4, and higher pooled entire cast deviations than T1 were demonstrated (P ≤ .027). CONCLUSIONS: The trueness of nanographene-reinforced casts was either similar to or higher than that of other casts. Dimensional changes were acceptable during the course of 1 month.


Assuntos
Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Maxila , Imageamento Tridimensional
3.
Int J Prosthodont ; 37(7): 133-141, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38498865

RESUMO

PURPOSE: To evaluate the flexural strength (FS) and microhardness of various CAD/CAM restorative materials intended for definitive use. The effect of hydrothermal aging on the mechanical properties of these materials was also investigated. MATERIALS AND METHODS: A total of 210 bar-shaped specimens (17 × 4 × 1.5 mm ± 0.02 mm) were fabricated via either subtractive manufacturing (SM) methods-reinforced composite resin (SM-CR), polymer-infiltrated ceramic network (SM-PICN), fine-structured feldspathic ceramic (SMFC), nanographene-reinforced polymethyl methacrylate (PMMA; SM-GPMMA), PMMAbased resin (SM-PMMA)-or additive manufacturing (AM) methods with urethane acrylate-based resins (AM-UA1 and AM-UA2). Specimens were then divided into two subgroups (nonaged or hydrothermal aging; n = 15). A three-point flexural strength test was performed, and five specimens from the nonaged group were submitted to microhardness testing. Specimens were subjected to 10,000 thermal cycles, and the measurements were repeated. RESULTS: Regardless of aging, SM-CR had the highest FS (P < .001), followed by SM-GPMMA (P ≤ .042). In nonaged groups, AM-UA2 had a lower FS than all other materials except SM-FC (P = 1.000). In hydrothermal aging groups, AM specimens had lower FS values than other materials, except SM-PMMA. With regard to microhardness, there was no significant difference found between any of the tested materials (P ≥ .945) in the nonaged and hydrothermal aging groups. CONCLUSIONS: The effect of hydrothermal aging on FS varied depending on the type of restorative material. Regardless of aging condition, SM-CR showed the highest FS values, whereas SM-FC had the highest microhardness. Hydrothermal aging had no significant influence on the microhardness of the tested materials.


Assuntos
Resistência à Flexão , Polimetil Metacrilato , Materiais Dentários , Resinas Compostas , Polímeros , Teste de Materiais , Propriedades de Superfície , Desenho Assistido por Computador
4.
J Prosthodont ; 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38502812

RESUMO

Computer-aided design and computer-aided manufacturing systems enable digital designing and 3-dimensional (3D) printing of definitive casts with removable dies. However, the fit of the removable dies should be without interferences for their accurate positioning in the cast. Given that the accuracy of additive manufacturing depends on design- and manufacturing-related factors, verifying the accuracy of the position of 3D-printed removable dies in their cast is essential to fabricate positionally accurate definitive prostheses, which would enable minimal or no laboratory and clinical adjustments. This dental technique article presents a straightforward approach to verify the seating of a 3D-printed removable die by using verification matrices made of a polyvinylsiloxane interocclusal registration material.

5.
Int J Prosthodont ; 37(7): 3, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38489215
6.
Int J Prosthodont ; 37(7): 19-29, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38489217

RESUMO

PURPOSE: To evaluate the effect of polymerization unit, polishing, and coffee thermocycling on the color and translucency of additively manufactured polyurethane-based resins with different viscosities. In addition, their color behavior was compared with the color of the shade tab throughout the fabrication steps and aging. MATERIALS AND METHODS: Disk-shaped specimens (Ø10 × 2 mm) were fabricated from polyurethane-based resins with different viscosities (Tera Harz TC-80DP and C&B permanent; n = 30 per material). Baseline color coordinates were measured after cleaning. The specimens in each resin group were divided into three subgroups (n = 10 per subgroup) to be polymerized with different polymerization units (Otoflash G171 [FLN], Wash and Cure 2.0 [CLED1], and P Cure [CLED2]), polished, and subjected to coffee thermocycling. Color coordinates were remeasured after each process. Color differences (ΔE00) and relative translucency parameter (RTP) values were calculated. Data were statistically analyzed (α = .05). RESULTS: Time points and polymerization units affected the ΔE00 for each material (P ≤ .049). ΔE00 of each polymerization unit pair had significant differences within and among different time points within each material (P ≤ .024). ΔE00 (when compared with the shade tab) and RTP were mostly affected by polymerization units and time points within both materials (P ≤ .042). CONCLUSIONS: Tested polymerization units, polishing, and coffee thermocycling affected the color difference and translucency of tested resins. Color differences ranged from moderately unacceptable to extremely unacceptable, and the differences in translucency values mostly ranged from perceptible to unacceptable, according to previous thresholds. In addition, tested resin-polymerization unit pairs had unacceptable color differences when compared to the shade tab. CLED1 may enable higher color stability for tested resins.


Assuntos
Café , Implantes Dentários , Polimerização , Poliuretanos , Cor , Teste de Materiais , Propriedades de Superfície , Resinas Compostas
7.
J Dent ; 144: 104941, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38490323

RESUMO

OBJECTIVES: To evaluate how restoration thickness (0.5 mm and 0.7 mm) affects the fabrication trueness of additively manufactured definitive resin-based laminate veneers, and to analyze the effect of restoration thickness and margin location on margin quality. METHODS: Two maxillary central incisors were prepared either for a 0.5 mm- or 0.7 mm-thick laminate veneer. After acquiring the partial-arch scans of each preparation, laminate veneers were designed and stored as reference data. By using these reference data, a total of 30 resin-based laminate veneers were additively manufactured (n = 15 per thickness). All veneers were digitized and stored as test data. The reference and test data were superimposed to calculate the root mean square values at overall, external, intaglio, and marginal surfaces. The margin quality at labial, incisal, mesial, and distal surfaces was evaluated. Fabrication trueness at each surface was analyzed with independent t-tests, while 2-way analysis of variance was used to analyze the effect of thickness and margin location on margin quality (α = 0.05). RESULTS: Regardless of the evaluated surface, 0.7 mm-thick veneers had lower deviations (P < 0.001). Only the margin location (P < 0.001) affected the margin quality as labial margins had the lowest quality (P < 0.001). CONCLUSION: Restoration thickness affected the fabrication trueness of resin-based laminate veneers as 0.7 mm-thick veneers had significantly higher trueness. However, restoration thickness did not affect the margin quality and labial margins had the lowest quality. CLINICAL SIGNIFICANCE: Laminate veneers fabricated by using tested urethane-based acrylic resin may require less adjustment when fabricated in 0.7 mm thickness. However, marginal integrity issues may be encountered at the labial surface.


Assuntos
Resinas Compostas , Adaptação Marginal Dentária , Materiais Dentários , Facetas Dentárias , Incisivo , Propriedades de Superfície , Humanos , Materiais Dentários/química , Resinas Compostas/química , Teste de Materiais , Planejamento de Prótese Dentária , Porcelana Dentária/química , Desenho Assistido por Computador , Cerâmica/química , Poliuretanos/química , Metacrilatos/química
8.
J Mech Behav Biomed Mater ; 151: 106395, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38244420

RESUMO

OBJECTIVES: To assess the mechanical durability of monolithic zirconia implant-supported fixed dental prostheses (iFDP) design on one implant, with a distal and a mesial extension cantilever bonded to a titanium base compared to established designs on two implants. MATERIALS AND METHODS: Roxolid Tissue level (TL), and tissue level x (TLX) implants were used to manufacture screw-retained 3-unit iFDPs (n = 60, n = 10 per group), with following configurations (X: Cantilever; I: Implant, T: Test group, C: Control group): T1: X-I-X (TL); T2: X-I-X (TLX); T3: I-I-X (TL); T4: I-I-X (TLX); C1: I-X-I (TL); C2: I-X-I (TLX). The iFDPs were thermomechanically aged and subsequently loaded until fracture using a universal testing machine. The failure load at first crack (Finitial) and at catastrophic fracture (Fmax) were measured and statistical evaluation was performed using two-way ANOVA and Tukey's post-hoc tests. RESULTS: The mean values ranged between 190 ± 73 and 510 ± 459 N for Finitial groups, and between 468 ± 76 and 1579 ± 249 N for Fmax, respectively. Regarding Finitial, neither the implant type, nor the iFDP configuration significantly influenced measured failure loads (all p > 0.05). The choice of implant type did not show any significant effect (p > 0.05), while reconstruction design significantly affected Fmax data (I-I-Xa < X-I-Xb < I-X-Ic) (p < 0.05). The mesial and distal extension groups (X-I-X) showed fractures only at the cantilever extension site, while the distal extension group (I-I-X) showed one abutment and one connector fracture at the implant/reconstruction interface. CONCLUSION: Results suggest that iFDPs with I-X-I design can be recommended regardless of tested implant type followed by the mesial and distal extension design on one implant abutment (X-I-X).


Assuntos
Implantes Dentários , Prótese Dentária , Zircônio , Suporte de Carga , Parafusos Ósseos , Análise de Variância , Titânio , Falha de Restauração Dentária , Análise do Estresse Dentário , Teste de Materiais , Coroas
9.
Int J Prosthodont ; 0(0)2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38227831

RESUMO

PURPOSE: The aim of this finite element analysis was to evaluate the stress distribution along a premolar's root dentin, its post, and post luting agent when materials with different elastic modulus are used to fabricate one-piece post-and-cores in 2 different design. MATERIALS AND METHODS: Two 3D virtual models (for cylindrical and conical post designs) of a mandibular premolar restored with one-piece post-and-core restorations were obtained by using a software. A total of eight post-and-core materials (polyether-ether-ketone (PEEK), polyether-ketone-ketone (PEKK), glass fiber-reinforced polyether-ether-ketone (GFR-PEEK), carbon fiber-reinforced polyether-ether-ketone (CFR-PEEK), gold-palladium alloy (Au-Pd), titanium (Ti), zirconia (Zi) and chromium-nickel (Cr-Ni)) were tested. Maxiumum principals stress (MPS) in the post, post luting agent, and root dentin were determined. A load of 150 N was applied to the buccal cusp in linguo-labial direction at an angle of 45° oblique to the longitudinal axis of the crown. RESULTS: The highest MPS value in post structure was observed with Cr-Ni material for both post designs. Similarly, the highest MPS value in the post luting agent was observed for Cr-Ni, the material with the highest elastic modulus. However, in the root dentin, the highest value was observed in PEEK, the material with the lowest elastic modulus. CONCLUSION: Post material and design influenced the stress concentration in the post, post luting agent, and root dentin. The stress at root dentin was slightly higher for polymeric materials. Cylindrical post design revealed lower stresses than conical post design at root dentin for all post-and-core materials tested.

10.
J Prosthodont ; 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38291720

RESUMO

Passive fit is essential for multiple-unit implant-supported prostheses. Conventional methods to assess the passivity of complete-arch implant-supported prostheses do not allow 3-dimensional (3D) visualization and quantification of misfit. This report describes the marginal and internal fit evaluation of a complete-arch implant-supported prosthesis by using the triple-scan protocol involving a scanner and a 3D analysis freeware. This technique allows researchers, clinicians, or dental technicians to detect and quantify 3D prosthetic misfit, which may facilitate the preparation for dental appointments and objective measurement of misfit for research studies.

11.
J Dent ; 141: 104830, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38163455

RESUMO

OBJECTIVES: This study compared the tooth morphology, internal fit, occlusion, and proximal contacts of dental crowns automatically generated via two deep learning (DL)-based dental software systems with those manually designed by an experienced dental technician using conventional software. METHODS: Thirty partial arch scans of prepared posterior teeth were used. The crowns were designed using two DL-based methods (AA and AD) and a technician-based method (NC). The crown design outcomes were three-dimensionally compared, focusing on tooth morphology, internal fit, occlusion, and proximal contacts, by calculating the geometric relationship. Statistical analysis utilized the independent t-test, Mann-Whitney test, one-way ANOVA, and Kruskal-Wallis test with post hoc pairwise comparisons (α = 0.05). RESULTS: The AA and AD groups, with the NC group as a reference, exhibited no significant tooth morphology discrepancies across entire external or occlusal surfaces. The AD group exhibited higher root mean square and positive average values on the axial surface (P < .05). The AD and NC groups exhibited a better internal fit than the AA group (P < .001). The cusp angles were similar across all groups (P = .065). The NC group yielded more occlusal contact points than the AD group (P = .006). Occlusal and proximal contact intensities varied among the groups (both P < .001). CONCLUSIONS: Crowns designed by using both DL-based software programs exhibited similar morphologies on the occlusal and axial surfaces; however, they differed in internal fit, occlusion, and proximal contacts. Their overall performance was clinically comparable to that of the technician-based method in terms of the internal fit and number of occlusal contact points. CLINICAL SIGNIFICANCE: DL-based dental software for crown design can streamline the digital workflow in restorative dentistry, ensuring clinically-acceptable outcomes on tooth morphology, internal fit, occlusion, and proximal contacts. It can minimize the necessity of additional design optimization by dental technician.


Assuntos
Aprendizado Profundo , Porcelana Dentária , Cerâmica , Coroas , Desenho Assistido por Computador , Planejamento de Prótese Dentária/métodos , Adaptação Marginal Dentária , Software
12.
J Prosthet Dent ; 131(2): 313.e1-313.e9, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37978007

RESUMO

STATEMENT OF PROBLEM: Knowledge of the fabrication trueness and margin quality of additively manufactured (AM) laminate veneers (LVs) when different intraoral scanners (IOSs) and finish line locations are used is limited. PURPOSE: The purpose of this in vitro study was to evaluate the fabrication trueness and margin quality of AM LVs with different finish line locations digitized by using different IOSs. MATERIAL AND METHODS: An LV preparation with a subgingival (sub), equigingival (equi), or supragingival (supra) finish line was performed on 3 identical maxillary right central incisor typodont teeth. Each preparation was digitized by using 2 IOSs, (CEREC Primescan [PS] and TRIOS 3 [TS]), and a reference LV for each finish line-IOS pair (n=6) was designed. A total of 90 LVs were fabricated by using these files and urethane acrylate-based definitive resin (Tera Harz TC-80DP) (n=15). Each LV was then digitized by using PS to evaluate fabrication trueness (overall, external, intaglio, and marginal surfaces). Each LV was also qualitatively evaluated under a stereomicroscope (×60), and the cervical and incisal margin quality was graded. Fabrication trueness and cervical margin quality were evaluated by using 2-way analysis of variance, while Kruskal-Wallis and Mann Whitney-U tests were used to evaluate incisal margin quality (α=.05). RESULTS: The interaction between the IOS type and the finish line location affected measured deviations at each surface (P≤.020). PS-sub and TS-supra had higher overall trueness than their counterparts. and the subgingival finish line resulted in the lowest trueness (P≤.005). PS and the subgingival finish line led to the lowest trueness of the external surface (P≤.001). TS-sub had the lowest intaglio surface trueness among the TS subgroups, and PS-sub had higher trueness than TS-sub (P<.001). PS-sub and PS-supra had higher marginal surface trueness than their TS counterparts (P<.001). TS resulted in higher cervical margin quality (P=.001). CONCLUSIONS: Regardless of the IOS tested, subgingival finish lines resulted in the lowest trueness. The effect of IOS on the measured deviations varied according to the surface evaluated and finish line location. The cervical margin quality of AM LVs was higher when TS was used.


Assuntos
Desenho Assistido por Computador , Imageamento Tridimensional , Fluxo de Trabalho , Técnica de Moldagem Odontológica , Modelos Dentários
13.
J Esthet Restor Dent ; 36(3): 477-483, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37877244

RESUMO

OBJECTIVE: The purpose of this in vitro study was to evaluate the effect of potassium aluminum sulfate (alum) application on the stainability and translucency of computer-aided design and computer-aided manufacturing (CAD-CAM) materials after coffee thermocycling (CTC). MATERIALS AND METHODS: Disk-shaped specimens (Ø10 × 1 mm; N = 200) were fabricated by using additively (Crowntec [CT] and Varseo Smile Crown Plus [VS]) and subtractively manufactured (Brilliant Crios [RCR], CEREC Block [FC], and Vita Enamic [VE]) CAD-CAM materials and polished. All specimens were randomly divided into two groups as alum applied and control (n = 10). All specimens were then subjected to CTC (10,000 cycles at 5-55°C) and color coordinates were measured at each time interval. Color differences (ΔE00 ) and relative translucency parameters (RTPs) were calculated and the data were statistically analyzed (a = 0.05). RESULTS: Among tested time intervals, alum applied specimens had their lowest ΔE00 after alum application (p ≤ 0.006), except for FC (p = 0.177). In addition, alum applied RCR had lower ΔE00 values than its control specimens (p = 0.029). Alum applied specimens had their lowest RTP after CTC (p < 0.001) and alum application decreased the RTP of CT (p = 0.010). CTC reduced the RTP of all materials in control groups (p < 0.001). Alum applied CT had higher RTP than its control specimens (p = 0.049). CONCLUSIONS: Alum application's effect on color change varied depending on the material and alum mostly resulted in clinically acceptable changes in translucency. CTC led to unacceptable color and translucency changes based on previously reported threshold values. CLINICAL SIGNIFICANCE: Optical properties of CAD-CAM materials and the sustainability of these properties over time is critical for longevity. Alum may improve the color stability of reinforced composite resin when subjected to long-term coffee consumption.


Assuntos
Compostos de Alúmen , Café , Porcelana Dentária , Cor , Teste de Materiais , Propriedades de Superfície , Cerâmica , Desenho Assistido por Computador
14.
J Esthet Restor Dent ; 36(3): 453-459, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37705502

RESUMO

OBJECTIVE: To evaluate the effect of coffee thermocycling (CTC) on the surface roughness (Ra ) and stainability of denture base materials with different chemical compositions fabricated by using additive and subtractive manufacturing. MATERIALS AND METHODS: Disk-shaped specimens were additively (FREEPRINT denture, AM) or subtractively (G-CAM, GSM and M-PM, SM) fabricated from three pink denture base materials in different chemical compositions (n = 10). Ra was measured before and after polishing, while color coordinates were measured after polishing. Specimens were subjected to CTC (5000 cycles) and measurements were repeated. Color differences (ΔE00 ) after CTC were calculated. Ra among different time intervals within materials was evaluated by using repeated measures analysis of variance (ANOVA), while 1-way ANOVA was used to evaluate the Ra of different materials within each time interval and the ΔE00 values. Color coordinates within each material were compared by using paired samples t-tests (α = 0.05). RESULTS: Ra before polishing was the highest for all materials (p < 0.001), while SM had its lowest Ra after CTC and AM had its lowest Ra after polishing (p ≤ 0.008). Before polishing, AM had the highest Ra among the materials (p < 0.001). After polishing, SM had higher Ra than AM (p < 0.001). After CTC, GSM had the lowest Ra (p ≤ 0.048). SM had the lowest (p ≤ 0.031) and AM had the highest (p < 0.001) ΔE00 . CTC decreased the a* and b* values of SM and AM (p ≤ 0.017), and increased the L* values of AM (p < 0.001). CONCLUSIONS: Polishing significantly reduced the surface roughness of all materials. CTC did not increase the surface roughness of materials above the clinically acceptable threshold. Only AM had perceptible color change when previously reported threshold values for denture base materials were considered. CLINICAL SIGNIFICANCE: Tested denture base materials may have similar surface stability after coffee thermocycling. However, subtractively manufactured denture base materials may have improved color stability when subjected to long-term coffee consumption.


Assuntos
Café , Bases de Dentadura , Propriedades de Superfície , Polimento Dentário , Teste de Materiais , Cor
15.
J Dent ; 141: 104820, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38128820

RESUMO

OBJECTIVES: This study aimed to investigate the antimicrobial properties of three dimensionally-printed dental polymers (3DPs) incorporated with microencapsulated phytochemicals (MPs) and to assess their surface characteristics and cytotoxicity. METHODS: MPs derived from phytoncide oil and their specific chemical components were introduced into suspensions of three microbial species: Streptococcus gordonii, Streptococcus oralis, and Candida albicans. Optical density was measured to determine the microbial growth in the presence of MPs for testing their antimicrobial activity. MPs at 5% (w/w) were mixed with dental polymers and dispersants to 3DP discs. These microbial species were then seeded onto the discs and incubated for 24 h. The antibacterial and antifungal activities of MP-containing 3DPs were evaluated by counting the colony-forming units (n = 3). The biofilm formation on the 3DP was assessed by crystal violet staining assay (n = 3). Microbial viability was determined using a live-dead staining and CLSM observation (n = 3). Surface roughness and water contact angle were assessed (n = 10). Cytotoxicity of MP-containing 3DPs for human gingival fibroblast was evaluated by MTT assay. RESULTS: MPs, particularly (-)-α-pinene, suppressed the growth of all tested microbial species. MP-containing 3DPs significantly reduced the colony count (P ≤ 0.001) and biofilm formation (P ≤ 0.009), of all tested microbial species. Both surface roughness (P < 0.001) and water contact angle (P < 0.001) increased. The cytotoxicity remained unchanged after incorporating MPs to the 3DPs (P = 0.310). CONCLUSIONS: MPs effectively controlled the microbial growth on 3DPs as evidenced by the colony count, biofilm formation, and cell viability. Although MPs modified the surface characteristics, they did not influence the cytotoxicity of 3DPs. CLINICAL SIGNIFICANCE: Integration of MPs into 3DPs could produce dental prostheses or appliances with antimicrobial properties. This approach not only provides a proactive solution to reduce the risk of oral biofilm-related infection but also ensures the safety and biocompatibility of the material, thereby improving dental care.


Assuntos
Anti-Infecciosos , Biofilmes , Humanos , Propriedades de Superfície , Anti-Infecciosos/farmacologia , Candida albicans , Compostos Fitoquímicos/farmacologia , Água
16.
Int J Prosthodont ; 36(6): 697-703, 2023 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-38109390

RESUMO

PURPOSE: To present prosthetic complications observed in the medium and long term in patients treated with metal-acrylic resin implant-supported fixed complete dentures (MAIFCDs). MATERIALS AND METHODS: A total of 87 patients who were treated with MAIFCDs were included. Acrylic resin (denture teeth and base) fracture, screw loosening (prosthetic or abutment), screw (prosthetic or abutment), and framework fracture were analyzed for descriptive statistics. Product-limit survival estimates were used for the cumulative no-complication rate (CNCR) of prostheses. All results were assessed using α = .05. RESULTS: The average observation time was 42.9 months (range: 19 to 153). Of 597 implants, 8 mandibular (44.4%) and 10 maxillary implants (55.6%) failed. In total, 29 patients (33.3%) experienced no complications in an average of 7 years, and 58 patients (66.6%) experienced at least one complication. The average time for the first complication to occur was 23 months (range: 1 to 97 months). The average number of complications was 5.9/patient. Acrylic resin complications were the most frequent, followed by screw loosening, screw fracture, and framework fracture. Of those patients with complications, 9 (16%) had maxillary MAIFCDs with an average of 4 complications. In total, 28 patients (48%) had only mandibular MAIFCDs with an average of 5 complications, and 21 patients (36%) had both arches treated with MAIFCDs with an average of 9 complications. Mandibular MAIFCDPs in women had a higher CNCR compared to maxillary MAIFCDs of both women and men and when both arches of women were treated with MAIFCDs (P < .05). CONCLUSIONS: The CNCR of MAIFCDs differed depending on the arch treated and sex. Mandibular MAIFCDs in women had a lower complication rate than MAIFCDs in other arch-sex pairs. Acrylic resin related complications were commonly observed as well as prosthetic screw loosening.


Assuntos
Resinas Acrílicas , Implantes Dentários , Masculino , Humanos , Feminino , Estudos Retrospectivos , Seguimentos , Falha de Restauração Dentária , Prótese Dentária Fixada por Implante/efeitos adversos , Prótese Total/efeitos adversos
17.
J Prosthodont ; 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37968565

RESUMO

PURPOSE: To compare the effect of coffee thermal cycling on surface roughness (Ra), Vickers microhardness (MH), and stainability of denture base resins additively manufactured in different layer thicknesses with those of subtractively manufactured denture base materials. MATERIALS AND METHODS: Eighty disk-shaped specimens (Ø10×2 mm) were fabricated from two subtractively (Merz M-PM [SM-M] and G-CAM [SM-G]) and three additively (NextDent 3D+ [50 µm, AM-N-50; 100 µm, AM-N-100], FREEPRINT Denture [50 µm, AM-F-50; 100 µm, AM-F-100], and Denturetec [50 µm, AM-S-50; 100 µm, AM-S-100]) manufactured denture base materials (n = 10). Ra measurements were performed before and after polishing by using a non-contact optical profilometer, while MH values and color coordinates were measured after polishing. Specimens were then subjected to 5000 cycles of coffee thermal cycling, all measurements were repeated, and color differences (ΔE00) were calculated. A linear mixed effect model was used to analyze Ra and MH data, while one-way analysis of variance was used to analyze ΔE00 data (α = 0.05). Ra values were further evaluated according to a clinically acceptable threshold of 0.2 µm, while ΔE00 values were evaluated according to perceptibility (1.72 units) and acceptability (4.08 units) thresholds. The interaction between the material type and the time interval affected both Ra and MH (p ≤ 0.001). Tested materials had their highest Ra before polishing (p ≤ 0.029). Before polishing, AM-F-100 had the highest, and SM-M and SM-G had the lowest Ra (p < 0.001). After polishing and after coffee thermal cycling, SM-G mostly had lower Ra than those of other materials (p ≤ 0.036). SM-G mostly had higher MH than that of other materials before and after coffee thermal cycling (p ≤ 0.025). Coffee thermal cycling reduced the MH of SM-M and increased that of AM-S-100 (p ≤ 0.024). AM-N-100 had higher ΔE00 than AM-F, AM-S-100, and SM-G (p ≤ 0.009), while AM-F and SM-G had lower ΔE00 than AM-S-50 and AM-N-50 (p ≤ 0.024). CONCLUSIONS: Polishing reduced the surface roughness of all materials, whereas the effect of coffee thermal cycling was nonsignificant. Most of the tested materials had acceptable surface roughness after polishing and after coffee thermal cycling according to the reported threshold. Layer thickness only affected the microhardness of tested additively manufactured resins, which was material-dependent. Subtractively manufactured specimens mostly had high microhardness and that of nonreinforced subtractively manufactured resin decreased after coffee thermal cycling. When reported color thresholds are considered, all materials had acceptable color stability.

18.
J Prosthodont ; 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37947220

RESUMO

PURPOSE: To evaluate the surface roughness, optical properties, and microhardness of additively or subtractively manufactured CAD-CAM materials after simulated brushing and coffee thermal cycling. MATERIAL AND METHODS: Two additively manufactured resins (Crowntec, CT and VarseoSmile Crown Plus, VS) and 3 subtractively manufactured materials (a reinforced composite (Brilliant Crios, BC), a polymer-infiltrated ceramic network (Enamic, VE), and a feldspathic ceramic (Mark II, VM)) were used to fabricate disk-shaped specimens (Ø10×1-mm) (n = 10). Surface roughness, Vickers microhardness, and color coordinates were measured after polishing, while surface roughness was also measured before polishing. Specimens were then subjected to 25000 cycles of brushing and 10000 cycles of coffee thermal cycling, and measurements were repeated after each time interval. Color difference (ΔE00 ) and relative translucency parameter (RTP) were calculated. Robust analysis of variance test was used to evaluate surface roughness, ΔE00 , and RTP data, while generalized linear model analysis was used for microhardness data (α = 0.05). RESULTS: Material type and time interval interaction affected tested parameters (p ≤ 0.002). In addition, material type affected all parameters (p < 0.001) other than surface roughness (p = 0.051), and time interval affected surface roughness and microhardness values (p < 0.001). Tested materials mostly had their highest surface roughness before polishing (p ≤ 0.026); however, there was no clear trend regarding the roughness of materials within different time intervals along with ΔE00 and RTP values within materials or time intervals. VS and CT had the lowest microhardness regardless of the time interval, while the remaining materials were listed as VM, VE, and BC in decreasing order (p < 0.001). Coffee thermal cycling only reduced the microhardness of VM (p < 0.001). CONCLUSIONS: Tested additively manufactured resins can be considered more susceptible to simulated brushing and coffee thermal cycling than the other materials, given the fact that their surface roughness and ΔE00 values were higher than previously reported acceptability thresholds and because they had the lowest microhardness after all procedures were complete.

19.
J Prosthodont ; 2023 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-37955870

RESUMO

PURPOSE: This in vitro study aimed to assess the positional accuracy during the sequence of static computer-assisted implant surgery (sCAIS) according to the anatomical characteristics of the alveolar ridge. MATERIAL AND METHODS: Maxillary bone models with six single tooth gaps including clinical scenarios of healed alveolar ridge (HR), single-rooted (SRS), and three-rooted socket (TRS) morphologies were used in this study. Positional deviations during implant placement procedures were evaluated after the pilot osteotomy (PD), final osteotomy (FD), and implant placement with respect to the pre-planned implant position by using a software package. ANOVA and post hoc analyses were performed. RESULTS: A total of 90 implants were included in this study. Higher mean angular, crestal, and apical deviations were found after the PD and FD (3.5 ± 2.4°, 0.7 ± 0.3 mm, and 1.4 ± 0.8 mm versus 3.6 ±2.2°, 0.6 ± 0.3 mm, and 1.2 ± 0.6 mm) compared to IP (2.8 ± 1.6°, 0.7 ± 0.3 mm, and 1.2 ± 0.5 mm, p ≤ 0.004). Implants placed in TRS demonstrated higher mean angular, crestal, and apical deviations (4.0 ± 1.7°, 0.8 ± 0.3 mm, and 1.6 ± 0.5 mm) compared to implants placed in SRS (2.5 ± 1.2°, 0.7 ± 0.3 mm, and 1.1 ± 0.4 mm) or HR (2.0 ± 0.9°, 0.5 ± 0.3 mm, and 0.8 ± 0.4 mm, p < 0.001). CONCLUSIONS: Positional deviations during sCAIS procedures are initiated with the first implant osteotomy and persist throughout the drilling sequence. However, deviations slightly decreased after implant placement. The alveolar ridge morphology is strongly associated with positional deviations. Higher deviations were observed in three-rooted and single-rooted sockets simulating an immediate approach compared to healed sites simulating a delayed protocol.

20.
Int J Prosthodont ; 0(0): 1-26, 2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-37988420

RESUMO

PURPOSE: To evaluate the effect of material thickness and coffee thermocycling on the optical properties of additively (AM) and subtractively manufactured (SM) definitive resin-based materials. MATERIALS AND METHODS: Specimens in 3 thicknesses (1 mm, 1.5 mm, and 2 mm) were prepared from 3 AM (3D-CB, 3D-TH, and 3D-CT) and 2 SM (G-CAM and VE) resin-based materials (n=15). Color coordinates of each specimen were measured after polishing and after 10000 cycles of coffee thermocycling. Color differences (ΔE00) and relative translucency parameter (RTP) values were calculated. After logarithmic transformation, ΔE00 values were analyzed with 2-way analysis of variance, while RTP values were analyzed with generalized linear model test (α=.05). RESULTS: 3D-TH had the highest and G-CAM had the lowest pooled ΔE00 (P≤.004). 3D-CB had higher pooled ΔE00 than VE and 3D-CT (P≤.002). SM specimens, 1.5 mm- and 2 mm-thick 3D-CT, and 1 mm-thick 3D-TH had lower ΔE00 than 1.5 mm- and 2 mm-thick 3D-TH (P≤.036). Most of the AM specimens and 1 mm-thick VE had higher ΔE00 than 2 mm-thick G-CAM (P≤.029). Most of the AM specimens had higher ΔE00 than 1.5 mm-thick G-CAM (P≤.006). RTP values of specimens were 3D-CT, G-CAM, VE, 3D-CB, and 3D-TH in an increasing order (P<.001). Increased thickness and coffee thermocycling mostly reduced RTP (P<.001). CONCLUSION: 3D-TH mostly had higher color change than subtractively manufactured specimens, while G-CAM mostly had lower color change than additively manufactured specimens. Only 1.5 mm- and 2 mm-thick 3D-TH had unacceptable color changes. Thickness and coffee thermocycling mostly reduced the translucency.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...